Swing Impact Seat Tester
TRIAX Touch Swing Seat Impact Tester is a free hanging spherical head form for impact testing of swing seats and related articles, compliant with ASTM F1487, En1176 and AS4685. Compatible with the TRIAX Touch and the existing TRIAX 2015 hand held units, this allows for the testing of swing seat impact in the laboratory, factory or field.
Please contact us for more information.
TRIAX Touch Swing Seat Impact Tester a free hanging spherical head form for impact testing of swing seats and related articles, compliant with ASTM F1487, En1176-2 and AS4685-6. Compatible with the TRIAX Touch and the existing TRIAX 2015 hand held units, this allows for the testing of swing seat impact in the laboratory, factory or field.
The TRIAX TOUCH dedicated hand held data unit connects wirelessly to the head form and collects and stores up to 1000 drop tests on a standard memory card. Use of a dedicated device provides data integrity and eliminates the need to download, install and configure apps. In addition a dedicated hand held unit guarantees continued successful operation of the TRIAX TOUCH system long after current crop of cellular phones and tablets have long since been discarded.
The TRIAX TOUCH system includes a PC application that speeds the creation and archiving of test reports, which show all impact test data along with a date / time stamp and user comments. The test results cannot be altered, particularly important to risk managers wanting to ensure data has not been tampered with should a legal action commence.
The TRIAX TOUCH system includes a PC application that speeds the creation and archiving of test reports, which show all impact test data along with a date / time stamp and user comments. The test results cannot be altered, particularly important to risk managers wanting to ensure data has not been tampered with should a legal action commence.
The TRIAX TOUCH is a sophisticated electronic measuring instrument. Like all electronic instruments, periodic factory calibration (at most once every two years) is required to ensure proper operation and compensate for variation inherent in all electronic devices. The TRIAX TOUCH system has a full factory calibration program in place and operating now. As with a new system, re-calibrated systems are supplied with a calibration certificate verifying that the calibration was completed as required, and should be supplied to users of testing services to prove compliance with standards.
To ensure proper operation between factory calibration the TRIAX TOUCH system is supplied with a reference mat that has been tested at the factory. Before each use the operator performs a set of drops on the reference mat and confirms that the results match those obtained by the factory when the TRIAX TOUCH system was freshly calibrated. If deviation beyond acceptable limits is observed this alerts the operator that the system needs attention and possible repair. The reference mat protocol prevents an operator from performing tests which would be inaccurate and a waste of time.